855-888-1894

Juuko K serie

Juuko K serie 2 pusbuttons to 16 pushbuttons single speed or double speed. Juuko K serie are bidirectionnel for all application with CSA CUL Approuved.

HV- K200-K1600

Model:
HV-K200 2 PUSHBUTTON SINGLE SPEED
HV-K400 4 PUSHBUTTON SINGLE SPEED
HV-K404 4 PUSHBUTTON DOUBLE SPEED
HV-K600 6 PUSHBUTTON SINGLE SPEED
HV-K800 8 PUSHBUTTON SINGLE SPEED
HV-K1000 10 PUSHBUTTON SINGLE SPEED
HV-K1200 12 PUSHBUTTON SINGLE SPEED
HV-K1600 16 PUSHBUTTON SINGLE SPEED
Solid states relays(Mofsets)
UP o 7.5 A (DC)Rated outputs
Syncronious input for PLC controls application
Compact receiving unit
12-24 dc operating voltage
Each systems includes 1 receiver and 1 transmitter
includes mounting hardware installation instructions
Transmitter(K200-K1600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Modulation method
4 FSK(433MHZ) OR 2 GFSK(915 MZ)
Typical operating range
300 ft(100 m)
Power suply
2 x 1.5 V AA Battery
Average power consumption
16ma @ 3VDC
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
188.5× 57.3 × 52.3mm (2-8 buttons)
Overall Dimensions
188.5× 57.3 × 52.3mm (10-10 buttons)
Overall Dimensions
188.5× 57.3 × 52.3mm (16 buttons)
Receiver(K200-K1600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Control system
PLL
Power suply
12-24 dc
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
142mm x 141mm x 58.5 mm
MOFSET Maximum Current
7.5 Amp (VDC)

H- K200-K600

Model:
H-K200 2 PUSHBUTTON SINGLE SPEED
H-K202 2 PUSHBUTTON DOUBLE SPEED
H-K400 4 PUSHBUTTON SINGLE SPEED
H-K404 4 PUSHBUTTON DOUBLE SPEED
H-K600 6 PUSHBUTTON SINGLE SPEED
Solid states relays(Relays 5 Amp/250 VAC)
UP 5 A (DC)Rated outputs
Bidirectional communications
Compact receiving unit
24-240 AC/24-160 DC operating voltage
voltage
Each systems includes 1 receiver and 1 transmitter includes mounting hardware installation instructions
includes mounting hardware installation instructions
Transmitter(K200-K600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Modulation method
4 FSK(433MHZ) OR 2 GFSK(915 MZ)
Typical operating range
300 ft(100 m)
Power suply
2 x 1.5 V AA Battery
Average power consumption
16ma @ 3VDC
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
188.5× 57.3 × 52.3mm (2-8 buttons)
Receiver(K200-K600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Control system
PLL
Power suply
12-24 dc
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
142mm x 141mm x 58.5 mm
Relay Maximum Current
10 Amp (VAC)

HS- K200-K1600

Model:
HS-K200 2 PUSHBUTTON SINGLE SPEED
HS-K202 2 PUSHBUTTON DOUBLE SPEED
HS-K400 4 PUSHBUTTON SINGLE SPEED
HS-K404 4 PUSHBUTTON DOUBLE SPEED
HS-K600 6 PUSHBUTTON SINGLE SPEED
HS-K606 6 PUSHBUTTON DOUBLE SPEED
HS-K800 8 PUSHBUTTON SINGLE SPEED
HS-K808 8 PUSHBUTTON DOUBLE SPEED
HS-K1000 10 PUSHBUTTON SINGLE SPEED
HS-K1006 6 PUSHBUTTON DOUBLE SPEED+4 SINGLE SPEED
HS-K1010 10 PUSHBUTTON DOUBLE SPEED
HS-K1200 12 PUSHBUTTON SINGLE SPEED
HS-K1212 12 PUSHBUTTON DOUBLE SPEED
HML-K1600 16 PUSHBUTTON SINGLE SPEED
Complies with UL 61010-1 and CSA C22.2
900 Mhz FCC, IC and CE certified
Solid states relays(Relays 5 Amp/250 VAC)
UP 5 A (DC)Rated outputs
Bidirectional communications
Compact receiving unit
24-240 AC/24-160 DC operating voltage
voltage
Each systems includes 1 receiver and 1 transmitter includes mounting hardware installation instructions
includes mounting hardware installation instructions
Transmitter(K200-K1600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Modulation method
4 FSK(433MHZ) OR 2 GFSK(915 MZ)
Typical operating range
300 ft(100 m)
Power suply
2 x 1.5 V AA Battery
Average power consumption
16ma @ 3VDC
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
188.5× 57.3 × 52.3mm (2-8 buttons)
Overall Dimensions
230×57×51mm(10, 12 buttons)
Overall Dimensions
290x57x51mm(16 buttons)
Receiver(K200-K1600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Control system
PLL
Power suply
12-24 dc
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
190×184×64mm
RELAY Maximum Current
5 Amp (VDC)

HLM- K1010/K1212/K1600

Model:
HLM-K1010 10 PUSHBUTTON DOUBLE SPEED
HLM-K1212 12 PUSHBUTTON DOUBLE SPEED
HLM-K1600 16 PUSHBUTTON SINGLE SPEED
Complies with UL 61010-1 and CSA C22.2
900 Mhz FCC, IC and CE certified
Solid states relays(Relays 5 Amp/250 VAC)
UP 5 A (DC)Rated outputs
Syncronious input for PLC controls application
Compact receiving unit
24-240 AC/DC operating voltage
Each systems includes 1 receiver and 1 transmitter
includes mounting hardware installation instructions
Transmitter(K1010-K1600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Modulation method
4 FSK(433MHZ) OR 2 GFSK(915 MZ)
Typical operating range
300 ft(100 m)
Power suply
2 x 1.5 V AA Battery
Average power consumption
16ma @ 3VDC
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
230×57×51mm(10, 12 buttons)
Overall Dimensions
290x57x51mm(16 buttons)
Receiver(K200-K1600)
Frequency
433 MHZ OR 902.5 ~ 927.5 MHz
Control system
PLL
Power suply
12-24 dc
Operating Temperature
(-20°C)~(+55°C)/(-40°C)~(+65°C)
Protection Degree
IP 65
Housing Material
PA6 (30% Glass filled)
Overall Dimensions
272×260×96mm
RELAY Maximum Current
5 Amp (VDC)
© 2024 JUUKO CANADA. All rights reserved.